Features

● Dual-point digital control
● RS485 + Genesis Network
● 2x control & 2x limit

More information:

Description

The Thermon Genesis Duo is an advanced microprocessor-based module designed specifically for heat tracing applications. This unit offers control and monitoring capabilities for one or two heat tracing circuits, with the flexibility to accept input from up to two RTDs per circuit. It can be configured to control and limit using dedicated RTD inputs for the limiter channel. The Genesis Duo features a 4.3” glove-touch-capable LCD display with an additional light ring for visual indication. Additionally, the Genesis Duo seamlessly integrates with the Genesis Network, eliminating the need for extra hardware to communicate with Thermon’s advanced supervisory and management platform.

PRODUCT FEATURES

The Thermon Genesis Duo control and monitoring unit offers the following key features:

Efficient Configuration and Operation: The 4.3” LCD, with glove-touch capability, allows operators to quickly program and access all readings. When connected to the Genesis Network, configuration and operation can be centrally managed for a distributed controls network.
Improved Control Methods: The Duo incorporates multiple control methods (On/Off, Soft-Start, Proportional) and introduces the enhanced Ambient Proportional Control (APC and APCM). This feature combines the energy-saving benefits of Ambient Proportional Control with the higher current capacity of the mechanical relay.
Upgraded Communications: As a Genesis Network native, the Duo comes with built-in wireless mesh or wired Ethernet. Optionally, it can be directly connected to any plant DCS system via Modbus RTU, with Modbus TCP support planned for a future update.
High-Temperature Limiter: The Duo can be configured as a single channel with a high-temperature limiter. This limiter functionality is isolated and includes dedicated RTD inputs. When enabled with the limiter function, the Duo complies with the requirements of IEC/EN/UL/CSA 60079-30-1 for controlled design to limit energy to the heat trace in explosive atmospheres.

GENESIS NETWORK

The Thermon Genesis Network comprises a control room server, a gateway, and an array of field-deployed bridges/nodes that create a wireless mesh communications network. Alternatively, the network can be established through a conventional wired Ethernet network. Connecting all heat trace panels and controllers to the control room, the Genesis Network provides visibility of all assets through a unified dashboard and user interface accessible from any browser.Thermon Genesis Duo integrated in the Thermon Genesis network

Product variants

SKU P/N Item Relay 4.3″ LCD Current monitoring Certification Mounting type
2025-001 816011 GN-D-S-S-T-C-Z-XP 2x SSR Yes Yes C1D2, Zone 2 Pipe
2025-002 816012 GN-D-S-S-T-C-Z-WP 2x SSR Yes Yes C1D2, Zone 2 Wall
2025-003 816021 GN-D-M-M-0-0-Z-XP 2x mechanical No No C1D2, Zone 2 Pipe
2025-004 816022 GN-D-M-M-0-0-Z-WP 2x mechanical No No C1D2, Zone 2 Wall
2025-005 816031 GN-D-S-L-T-C-Z-XP 1x SSR, 1x limiter Yes Yes C1D2, Zone 2 Pipe
2025-006 816032 GN-D-S-L-T-C-Z-WP 1x SSR, 1x limiter Yes Yes C1D2, Zone 2 Wall

THERMON-DS-GENESIS-DUO-TEP0260-0723.PDF

Datasheet

Additional information

Control and monitoring capacity

2 heat tracing circuits

Supply and load voltages

100-277 V~, 50/60 Hz

Max. input current

1.5 A

Fuse rating

3.15 A

Heater Outputs (each circuit independently powered and switched)

Input Voltage: 100-277 V~, 50/60 Hz
Output Current: (See derating) 30 A~
Ground fault measurement: up to 500 mA
Heater current measurement: up to 60 A
Voltage measurement (for power calculation): up to 277 V

Power clamp function

Programmable from 20%-100%

Temperature input

Up to two, 3-wire platinum 100 Ohm RTDs per circuit

Temperature control range

-40°C to 600°C

Control band

Programmable in increments of 1 degree

Dry contact alarm relay

Two 277 V~, 500 mA or higher

Aux Input

Contact closure sensed

Self-test frequency

Programmable from 2 to 99 hours

Communication

Wired: Modbus (RS-485)
Wireless: Mesh via 802.15.4 Radio or WiFi 802.11 bgn

Auxiliary power output

9 W @ 24 Vdc

Pollution degree

2

Degree of protection and type rating

IP66, Type 4

Operating temperature range

-40°C to +60°C (see derating curve)

Storage temperature range

-40°C to +85°C