FP

Features

● 8, 15, 24 & 33 W/m
● Tmax maintain 65°C
● 110-120, 208-277, 400 & 575 Vac

More information:

Description

Thermon FP parallel resistance constant wattage heating cables are designed for freeze protection and process temperature maintenance, supporting temperatures up to 65°C. Suitable for installation on piping, tanks, vessels, and equipment, FP heating cables demonstrate resilience with continuous exposure temperatures of up to 204°C when powered off. All FP heating cables come with a fluoropolymer (OJ) overjacket, providing robust chemical resistance against aggressive organics and corrosives.

The parallel resistance configuration allows easy field termination and customization with user-friendly Thermon kits. FP heat trace cables deliver consistent and reliable heat outputs across various circuit lengths, without the inrush current associated with self-regulating heating cables. This eliminates the need for oversizing power distribution equipment.

Approved for use in ordinary (nonclassified) areas, hazardous (classified) areas, and Zone 2 classified areas, FP heating cables offer versatile and dependable solutions for diverse environments.

Features

  • Pipe freeze protection and temperature maintenance up to 65°C
  • Maximum exposure temperature of 204°C
  • Extended circuit lengths of up to 399 meters
  • Available service voltages 120, 240, 400 and 575 Vac
  • Cut-to-length parallel circuitry
  • Nichrome heating element
  • 4 mm² copper bus wires
  • Metallic braid for grounding purposes
  • Fluoropolymer (OJ) overjacket
  • Worldwide approvals
  • Compatible with user-friendly and easy to install Thermon components

Product variants

SKU P/N Item Power output Zone length Voltage (Vac) Outer jacket
2002-001 22332 FP 2.5-2-OJ 8 W/m, 230 Vac 137 cm 230-240 Fluoropolymer
2002-006 FP 2.5-1-OJ 8 W/m, 120 Vac 76 cm 120 Fluoropolymer
2002-002 22342 FP 5-2-OJ 15 W/m, 230 Vac 102 cm 230-240 Fluoropolymer
2002-007 FP 5-1-OJ 16 W/m, 120 Vac 61 cm 120 Fluoropolymer
2002-003 22387 FP 8-2-OJ 24 W/m, 230 Vac 102 cm 230 Fluoropolymer
2002-008 FP 8-4-OJ 18 W/m, 400 Vac 152 cm 400 Fluoropolymer
2002-004 22352 FP 10-2-OJ 33 W/m, 230 Vac 76 cm 230-240 Fluoropolymer
2002-009 FP 10-1-OJ 33 W/m, 120 Vac 61 cm 120 Fluoropolymer
2002-005 22362 FP 10-4-OJ 23 W/m, 400 Vac 137 cm 400 Fluoropolymer
2002-010 FP 10-5-OJ 33 W/m, 575 Vac 168 cm 575 Fluoropolymer

THERMON-DS-FP-TEP0016U-0113.PDF

Datasheet

Additional information

Max. watt density

33 W/m

Max. operating voltage

690 Vac

Max. maintenance temperature

65°C

Max. exposure temperature

Continuous (power-off): 200°C

Min. installation temperature

-60°C

Min. bend radius

10 mm @ -15°C
19 mm @ -60°C

T-rating

Based on stabilized design: T3 to T6